The infectious material is temporarily held in a waste container(s) which in turn, are emptied into an pre storage hopper via a charging system which is located at the front of the MDU, The infectious waste is fed to the shredding system by a feed arm where it is shredded. The shredded material is conveyed through a microwave section and temperature holding section, respectively for disinfection, with microwave of 2450MHz (±50MHz), temperature ≥95℃, with over 45minutes. The disinfected and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.